an image

QR4 RELAY

4 CHANGE-OVER CONTACTS, 14 FASTON, FPDT.

QR4 Relay

QR40L Relay
QR4 connection diagram

QR4 connection diagram

Electrical life AC load

Electrical life AC load

Max.DC breaking capacity

Max.DC breaking capacity

QR4 dimensions

QR4 dimensions

TECHNICAL APPROVALS

TYPE

QR40L …V

Miniature Power Relay 4 change-over contacts

DOWNLOADS

CONTACT

Max.Contact load 5A/250V AC1
5A/30V DC1
Material AgNi -Standard
Rated current 5 A
Max. peak current 15 A
Rated voltage 250 V
Max. switching voltage AC-1 250 V (Same Polarity)
Rated load AC15 (250 V) 350 VA
Min. switching load 10V / 10mA

COIL

Operation range ≤0,8 x UN – 1,1 x UN
Rated power (AC/DC) 1,5 VA /0,9 W
Release voltage ≥0,1xUN
Coil resistance ±10%

COIL DATA

VAC Ω mA VDC Ω mA
24 174 50 12 148 81
48 686 25 24 594 40
115 4K3 10,4 48 2K3 21
230 18K6 5,2 110 11K4 11

INSULATION (Vrms, 1 min)

Contact open 1 KV
Coil /Contacts 2,5 KV
Insulation IEC 61810-1 2,5 KV /3
Between contacts 2 KV

SPECIFICATIONS

Ambient temperature -40 ºC … +65 ºC
Operation time ≤ 20 ms
Release time ≤ 20ms
Protection category IP40
Electrical life DC 1-105 op
Mechanical life 10-105 op [AC] 20-106 op [DC]
Weight 35 gr

TECHNICAL APPROVALS

SOCKETS